SISTEM MONITORING DATA METERAN AIR PELANGGAN PDAM MENGGUNAKAN MIKROKONTROLER ATMEGA 16

Authors

  • Herdianto Herdianto Sistem Komputer Universitas Pembangunan Panca Budi Medan
  • Ayu Nuriana Sebayang Teknik Informatika STMIK Logika, Medan, Indonesia
  • Darmeli Nasution Sistem Komputer Universitas Pembangunan Panca Budi Medan

DOI:

https://doi.org/10.30865/komik.v1i1.469

Abstract

The purpose of this research is to design a monitoring system of PDAM customer water meter data using ATMEGA 16 microcontroller and to know the accuracy of the system that has been designed. The results of this research will be expected to help the PDAM (local water company) in overcoming the existing problems regarding the recording of water meter data is not accurate. In this research there are 5 sample of meter data which used by method used is demonstration application. In the research of monitoring system of customer water meter data there are 2 forms of testing conducted that is the testing of water flowmeter sensor and data transmission GSM SIM 800. From the test results accuracy of flowmeter water sensor reaches 100% while GSM SIM 800 data transmission only 95%.

References

Irawati, Zahir Zainuddin dan Syafruddin Syarif, 2014. Sistem Pencatatan Meteran Air Mobile PDAM Untuk Komsumsi Air Bersih Akurat Dan Fleksibel Berbasis Image Processing. Makassar. Jurnal teknik Elektro. Moch. Adib Musyafa, Susijanto Tri Rasmana dan Pauladie Susanto, 2015. Rancang Bangun Sistem Prabayar Pada PDAM Berbasis Arduino Uno R3. Surabaya. Journal of Control and Network Systems, Vol. 4 No.1. Raharjo B.N, Widodo S.T dan Susanto A, 2010. Sistem Monitoring Volume Air Pada Meteran Air PDAM Menggunakan Media Komunikasi SMS, Bandung. Jurnal Penelitian Teknik Elektro. Syahrul dan Rahardjo P, 2013. Aplikasi Pencatatan Meteran Air Berbasis Smartphone android, Bandung.Jurnal teknik Informatika UNIKOM.

Downloads

Published

2017-11-13